Best Prices on Sewage Wastewater Chlorine Tablets and Tablet Feeders

B&B Alternative Septic Solutions, LLC is a proud NORWECO distributor for over 12-years.  We provide all NORWECO products at the best online prices available.  Our products include Bio-dynamic Tablet Feeders, all NORWECO’s chlorination and dechlorination tablets sewage pump stations and wastewater treatment systems such as SINGULAIR products. We offer the best on-line prices for Septic Chlorine Tablets and Tablet Feeders. We won’t be undersold.

NORWECO Bio-Dynamic Tablet Feeders

NORWECO Wastewater Disinfection Tablets


NORWECO Packaged Pump Units

Our wastewater engineers are registered professionals who can answer your wastewater treatment needs.  Unlike most NORWECO distributors, our registered engineers give you the technical help you need to complete a successful project. We are here to help.

We are firm believers that the NORWECO wastewater line of products are the best in the world.  NORWECO’s biodynamic tablet feeders have been in production for over 50 years which go through continuous improvement processes on a regular basis.  NORWECO’s dedicated professional team produces made in America products which are the best in the world.

Due to online volume sales we are able to offer the best prices in America for NORWECO products.  If a competitor supplier offers our line of products at a reduced advertised prices, contact us and we will match it.  We will NOT be undersold.

Remember, we are the only NORWECO distributor run by professional engineers.  We can give you sound technical advice on all our product lines.  If you have any questions please feel free to contact us at bosshardeng@aol.com.

Enhanced by Zemanta

Sewage Wastewater Lift Pump Design Considerations

Properly designed Wastewater Lift pump systems require some basic attention that most plumbers just fail to address. When designing your Sewage lift unit, we recommend that you consult a registered engineer to ensure that your system will work reliably for years.

We reviewed internet posts, which present guidance for homeowners and plumbers to use when choosing a Sewage wastewater lift system. Most of the internet “advice” we reviewed fails to consider some critical pump design elements. This article attempts to highlight a few minimal design considerations which we feel should be addressed.

Firstly, what type of wastewater requires pumping? For example, various sewage pumps can pass different size solids from small quarter inch pieces to up to 2.5 inches in diameter. For larger size solids, grinder pumps are used, much like a garbage disposal, to chop up the solids into smaller particles that can be pumped. Therefore, if we are pumping screened or filtered wastewater, a liquid pump is adequate. The liquid pumps are generally multi-staged pumps and can deliver a high head (pump outlet pressure). If solids are screened in larger pieces, then specially designed lift pumps can be used which can pass the larger solids.

All pumps require a minimum net positive pump suction head (NPSH) to minimize cavitation. If the pump cavitates excessively, then the impeller will wear out, possibly in a year or so. A properly design system ensures that the correct pump is chosen which will match the system, minimizing cavitation and extending pump life.

The figure below is pump curves for the basic NORWECO wastewater lift units and a “typical pump placement.” The pump curves are the curves bending downwards. Each pump has a different application and you select the appropriate pump based on the desired lift height and the resulting system curve. The system curve, in this example, curves upward. Where the pump and system curves meet yields the flow rate and pump lift height when the pump is running. Generally, you meet NPSH requirements if the pump curves intersect without extrapolation.

The system curve should ALWAYS be calculated as noted in the bottom of figure one. The calculation ensures that the pumps operate in an acceptable range. As a homeowner or contractor, you should ALWAYS ask to see the pump and system curves for your application. Please do not trust an installation that does not perform the calculation, force your plumber or engineer to provide one.

One additional consideration is the pump chamber height and/or lift. I notice many “sewage pump units” offered on the internet. The pump units are short and fat sumps. We estimate that these systems are very inadequate. When the pump sump height is too low, the pump will tend to short cycle. The “short cycling” can cause excessive pump wear. Also, the on/off and alarm settings tend to be unreliable due to the short travel distance (the pump sump height is much too small) in liquid height. In the NORWECO pump units, you adjust the pump sump heights are by adding segments to the sump. This gives the design engineer flexibility in pump designs which ensure maximum pump cycle times and proper NPSH.

Please consider our line of NORWECO lift stations. Our pricing is very competitive and we do maintain staffs of registered engineers, which can provide complementary lift pump calculations with every purchase. We feel that the NORWECO pump units are the best pump units on the market today.

Enhanced by Zemanta

Modern Commercial Sewage Lift Stations

Bruce Hardboss, PE

Sewage pump stations which can be utilized in sewage collection methods, also known as lift stations, are frequently made to handle raw sewage

The ABS EffeX range of submersible sewage pump...

Image via Wikipedia

that’s supplied through subterranean gravity-given pipelines (piping that happens to be laid in a location to make sure that a liquid can easily flow one path subjected to gravity). Sewage is given directly into and saved within below grade tank, generally referred to as a wet well. The well is usually equipped by having electro-mechanical instrumentation to measure the amount of sewage available. Whenever the sewage level goes up to some predetermined point, a pump motor will be began to raise up the sewage ” up ” by means of a pressurized conduit system termed as a sewer pressure main or maybe rising primary in which the sewage is discharged right into a gravity manhole. Then the pattern commences all over again before the sewage reaches its destination – often a treatment plant. With this method, lift stations are utilized to move waste to greater elevations. Within the situation of high sewage flows in to the well (for instance throughout peak flow periods and wet weather) additional pumps are generally used. If this sounds like inadequate, or perhaps in the situation of failure from the moving station, the sewer system can back up, resulting in a sanitary sewer overflow – the release of raw sewage in to the environment. Most facilities are quite concerned about the hazards of raw sewage releases. For example, in San Diego, CA, the beaches were shut down following most major rainfall events due to sewage releases. The bad press over many years prompted San Diego to build it’s new Point Loma facility.

Sewage pumping stations are usually designed to ensure that one pump or multiple pumps will handle normal peak flow conditions. Redundancy built  into the system to ensure that when anyone pump has run out of service, the rest of the pump or pumps will handle the designed flow. Present day designs include lots of electronic remotes on the market designed specifically with this application. The storage amount of the wet well between your ‘pump on’ and ‘pump off’ configurations are designed to minimize pump on-off cycles, however is not such a long enough retention time to promote septic conditions in the tank wet well. If the sewage remains static for too long a period of time, then ecessive corrosion and/or explosive conditions can occur. Also, some regulatory bodies require a minimum height to cross-sectional area requirement to minimize these effects.

Sewage pumps are nearly always centrifugal pumps with open impellers and therefore are specifically fashioned with a sizable open passage in order to avoid blocking with debris or winding debris around the impeller. A 4-pole or 6-pole AC induction motor normally drives the pump. Some pumps do not rely the ability to pass large solids, and typically more compact sewage pumps,  macerate any solids inside the sewage breaking them into more smaller parts which can easily pass through the impeller.

The inside of the sewage pump station is an extremely hazardous. Poisonous gases, for example methane and hydrogen sulfide, build up within the wet well an ill-outfitted person entering the well could be rendered unconcous very rapidly. Any entry in to the wet well necessitates the correct limited space entry of a hazardous atmosphere. To reduce the requirement for entry, the wet wells are generally located outside, which minimizes some confined space entry concerns.

Traditional sewage lift stations incorporate both a wet well along with a ‘dry well’. Frequently fundamental essentials same structure separated by an interior divide. Within this configuration pumps are installed on the bottom of the dry well to ensure that their basins are below level of pump start, priming the pump as well as increasing the accessible NPSH. Although nominally isolated in the sewage within the wet well, dry wells are subterranean, confined spaces and require appropriate safeguards for entry. Further, any failure or leakage from the pumps or pipe-work can discharge sewage into the dry well with complete flooding. Consequently, the electrical motors are usually mounted over the overflow, top level from the wet well, usually above walk out, and drive the sewage pumps with an extended vertical shaft. To safeguard the above mentioned ground motors from weather, small pump houses are usually built, that also incorporate the electrical switch-gear and control electronics. Fundamental essentials visible areas of a conventional sewage moving station even though they are usually more compact compared to subterranean wet and dry wells.

More contemporary sewage pumping stations don’t require a dry well or pump house in most cases comprise merely a wet well. Within this configuration, submersible sewage pumps with a combined motor unit are mounted inside the wet well itself, immersed inside the sewage. Submersible pumps are installed on two vertical guide rails and seal onto a permanently fixed ‘duckfoot’, which forms both a mount in addition to a vertical bend for the discharge pipe. Maintenance is performed by elevating the submersible pumps with a chain from the duckfoot, or they are extracted by guide rails to the maintenance (normally at the ground surface) level. The pumps are re-installed by simply reversing this procedure. Because the motors are sealed and weather isn’t a concern, no above ground structures are needed, except a control panel which contains the electrical switch-gear and control systems. In the past 20-years or so, pump materials have allowed us to design sealed submersible-pumps that can withstand being submerged in relatively caustic conditions. In the 1960′s and earlier, few true submersible pumps were available, therefore pump stations that contain large dry-wells were predominant. Modern sewage lift stations rely almost exclusively on submersible pumps.

When we balance safety and reliablility concerns, and require more compact footprint and visibility, submersible pump sewage pumping stations have almost completely replaced traditional sewage lift stations. Further, a refit of the traditional pumping station usually involves transforming it right into a modern lift station by setting up submersible pumps within the wet well, destroying the pump house. Wet well designs, utilizing submersible pumps are the future of wastewater lift stations.

Enhanced by Zemanta

Options For Sewage Lift Stations Of Today

Traditional sewage lift stations work well, but can have their drawbacks. Thanks to modern methods, there are options which can increase efficiency and save money. There are also other important benefits to consider. Here is a look at traditional pumping methods and how they can be improved.

A waste water pumping station is necessary whenever the problem of higher elevations is faced. A conventional station for pumping includes a dry well, as well as a wet well. Both wells are in the same general area for efficiency, and are often part of the same structure. The dry well contains the pump motors and their inlets extend below ground level into the wet well. This configuration allows for automatic pump priming. It also allows for the highest net positive suction head, also known as NPSH. NPSH is needed for an effective hydraulic system.

A conventional sewage lift station pump has a dry well with pumps mounted above the ground. This is done to protect them from any flooding. Pump motors incorporate long shafts and they extend into the wet well area. As pumps are above ground, they must have protection from the elements, in the form of a housing.

Modern day options include package sewage lift systems. They offer a great deal of convenience and eliminate the need for dry wells. The package system is usually complete from the factory and comes with the wet well, pumps, pipes, valves, control panels, junction boxes, and an alarm system.

Packaged pumping stations feature pumps that are submersible. They can be either grinder pumps or solid handling pumps. The wet well in this kind of system is not intended for storage and its simple operation requires fewer controls than conventional systems.

A packaged pumping station provides a lot of benefits over other kinds. As the pumps are submerged, the entire operation takes place under the ground. The pumps do not require special protection from the weather, so no special housing is required. There is not a great deal of maintenance needed on a packaged system, either.

Packaged pumping stations are easy to install, and everything that you need comes with the kit. Life expectancy of these systems can be as long as 20 years, which is above average. These systems take up a smaller footprint on the land, as the only visible structure houses the control panel. Everything else is below ground, as the pumps are completely submerged. Also, many of these systems are designed to handle high capacity and have redundancy features in the event of one pump not working.

Sewage lift stations have many options today. For example, there is no need to have a dry well, as in the past. Modern systems include the use of a packaged pumping station which comes complete from the factory. These systems are easy to install and maintain, and can save a lot of money on operating costs. It is an excellent way to increase the efficiency of a modern day waste system.

Enhanced by Zemanta

Drinking water Injury Burnaby: Hidden Risks Of Sewage Lift Stations Back Up

Burnaby

Image via Wikipedia

Drinking water restoration right after a sewer backup flood is no joke. This kind of catastrophe can deliver about devastation, not just to your belongings but to your health as nicely. There are a lot of home contractors in Burnaby and throughout Higher Vancouver that provide specialist restoration services for residents and businesses. These organizations have lifted the weight off the shoulders of hundreds of people.
There are numerous positive aspects to using a skilled h2o restoration and fix company in comparison to undertaking it on your individual. For one particular factor, it is pretty not likely that you have the appropriate devices to efficiently cleanse your home and dry it out extensively. If the career is not performed properly, you danger additional damage and repairs in the foreseeable future because of to the probability of structural injury, mildew and other pathogens that can hide in unseen places. Experts will have the needed gear to test for dampness and air quality, in addition to properly cleaning and restore your furnishings and your residence, which would otherwise take you so much time, work and funds ought to you try to undertake this on your own.
Nonetheless, far more crucial than the gear, is that there are some significant wellness hazards in making an attempt to undertake sewage again up restoration by yourself. The variation that sewer drinking water has from other sorts of flood h2o is that with sewage you are placing yourself and your household at chance of serious well being troubles because of to the pathogens that are soaking into your personal belongings and creating structure, as nicely as pathogens that turn out to be airborne and circulate during the residence. It is actually a dangerous task that calls for specialised coaching and strict health and basic safety rules. To take this sort of fix on by by yourself would be inviting critical well being potential risks.
As with any form of drinking water hurt, you must also contemplate that the damage is still getting performed even right after the h2o amounts have gone down. This is because the development of mold gets to be a lot much more common when there is a increased amount of humidity. Mold has a unpleasant behavior of hiding in tough to achieve areas, areas in which you would not feel to look. So hiring pros is a fantastic way to be in a position to see if there is mold growing in concealed areas. This will make sure your family’s security since mold can also trigger a selection of diseases.
All in all, it is hugely suggested that you to retain the services of professional h2o hurt contractors to do the function for you. This will ensure your security along with your family’s, and enable you to sense more at ease and relaxed throughout the restoration approach.

Copyright 2010 Masters Remediation Companies. We present emergency h2o hurt restoration solutions to homes and businesses in Burnaby and all the way through Greater Vancouver. We take pride in providing leading top quality workmanship and exceeding expectations. Watch these limited videos guidelines to aid in situation of flood: http://mastersremediation.com/video clip-web site/video clip_flood.html
Get a Free CHECKLIST to avoid additional damage and lengthy repairs… and get a Gift for New Buyers: http://mastersremediation.com/flood/freeguide.html

A lot more Sewage Elevate Content articles

Enhanced by Zemanta

Undertaking Leak Detection In Your Sewage Pipes

 

Article by Andrew Jackson

Having a leaking sewerage briar in your home or on your place tin prove to be I of the most unpleasant place related problem that tin occur. The odor that such a job cause is often extremely unpleasant and in some suit tin stucco your place uninhabitable. In improver to the horrible malodour, there is also a very imaginary menace of wellness hazard from taint right to bacterium and harmful mould. With this in brain it is modality that you packing putout prompting hole sensing in the act that you somebody you have a job with your sewerage pipe. Read on for helpful tip on how to place a hole in your sewerage pipes.

System obstruction or accretion

Most sewerage leaks will be caused by a cracked or collapsed pipe. This kind of damage will often cause the sewerage system to backup or be completely blocked as debris tin went caught. So your former step in hole detection should be to fill your bath and sinks and then pull out all the plugs at the Lapp time. If they take longer to drain then usual then there is a commonweal chance that the problem is situated within your property rather than a neighbours.

Water protrusion

In some cause you whitethorn be able to follow the odour and return a commonweal indicant of where the job lie. If the job prevarication within the dwelling then it will be hard to Archer exactly where the hole is without lifting up the floorboard, but you should be able to sound it plume to an area. In stance where the odor seems to be approaching from exterior then you should always cheque for H2O extrusion seeping through writer, globe and any pavement slab.

Stained wall

Leak sensing in multi-storey flats tends to be much easier due to the here of sewage pipes. If you do have a problem then you will usually be able to tell due to the fact that it will discolouration your walls. Or possibly it will discolouration the walls of the unlucky person living beneath you

Enhanced by Zemanta

Wastewater Treatment _ De-centralized vice Centralized Sewage Treatment.

Industrial wastewater effluent with neutralize...

Image via Wikipedia

USBF (TM) Misuse Water Treatment System for the Tonto Apache Tribe in Payson, Arizona. The plant has a capacity of eighty thousand gallons per day (regular) it serves the “Maztal Casino, Resort & Conference Middle” and it serves other services in the reservation these kinds of as housing, tribal administration amenities and gentle commercial stores.

When considering WWTP designs BnB generally likes to see more De-centralized wastewater treatment. We strongly feel that limits should be placed on how far we pump our waste streams. At the minimum a 30/30 (BOD/TSS) treatement should be considered if pumping the sewage in excess of a one-mile distance. For example in San Diego, CA every heavy rainfall generally causes relief valves to lift and raw sewage is released into the washes. This causes hazardous pathogen levels in nearby beaches for days or weeks.

By treating wastewater in nodes and then pump the treated water vice raw sewage, releases have minimum environmental hazards/impacts. We advocate distributive treatment vice large-mega centralized treatment to minimize these sewage transfer hazards.

BnB opinion.

Enhanced by Zemanta

Commercial Wastewater Pumping Stations Review of Bio-microbics’ BioSTEP® and NORWECO

 

Article By Bruce Hardboss, PE

 

 

BioSTEP® screened pumping schemes are versatile ticker packet designed to transferral screened liquid in numerous size-diam, decentralized accumulation applications. BioSTEP® is a registered trademark of Bio-MICROBICS.  Bio-MICROBICS claims the following; “BioSTEP® screened pumping systems are designed so that once installed, all normal operation and maintenance can occur without the messy removal of system components. BioSTEP screened pump vaults utilize the patented SaniTEE® screening technology to screen and deflect solids rather than collect and hold them like other filtering technologies. ” (see http://www.biomicrobics.com/?p=67&s=10) This article is the sole property of BnB Alternative Septic Solutions, LLC and does not necessarily reflect NORWECO’s position. We feel that our evaluation is technically correct and we welcome constructive comments.

At BnB Alternative Septic Solutions, LLC our registered professional CIVIL Engineers prefer simple NORWECO grinder pump configuration(s) or the robust BK-2000 filtration system followed by a standard NORWECO pump unit. Bio-MICROBICS advocates their BioSTEP® product as superior to filtration systems. We strongly feel that for flows up to 2000 GPD, a BK-2000 system provides robust filtration and is a simpler approach when compared to the BioSTEP® system. We also feel that adding grinder pump units to a standard septic tank outlet is also a “more simple design.”

Either a NORWECO pump vault or a simple grinder pump installation in the septic tank fluids compartment or a BK-2000 filtration unit paired with a standard lift pump unit will give comparable performance and possibly increased reliability. We have seen very few problems with particle clogging.

We recommend adding NORWECO Bio-Gem organic digester or Bio-PERC to the wastewater up-stream to promote solids breakdown to any configuration, including the BioSTEP®. A typical NORWECO pump package would be as noted below:

Typical NORWECO Pump Package

(There are multiple configurations available)

Also, a good option which is robust and similar to the Biomicrobic’s approach is to add a BK 2000 filtration unit to the septic tank outlet, then feed the filtered outlet to the above pump unit. In this case a single liquid pump is adequate since solids are removed and TSS is lowered to under 10 mg/L.

Enhanced by Zemanta